Solid-state Timer
H3JA
Economical, Compact, Plug-in Timer
■ Time limit operation with automatic resetting.
■ DIN size (36 × 36 mm), fits standard 8-pin sock-
ets.
■ Wide choice of supply voltages:
24, 100 to 120, 200 to 240 VAC, 12, 24 VDC.
■ Dual LED indication for power and output sta-
tuses.
■ Large transparent setting knob.
■ Setting error rating almost matches that of a 48 ×
48 timer.
■ Conforms to UL and CSA, and meets CE marking
requirements.
Ordering Information
Operation/resetting
system
Time-limit operation/
self-resetting
Note:
Time-limit contact
SPDT
Mounting method
Surface mounting, flush
mounting, and DIN track
mounting
DPDT
Rated time
Model
1 s, 3 s, 5 s, 10 s, 30 s,
H3JA-8A
60 s, 3 min, 5 min, 10 min,
H3JA-8C
30 min, 60 min, 3 hrs
Specify the model number, supply voltage, and rated time when ordering.
Ex. H3JA-8A 100 to 120 VAC 1 s
Rated time
Supply voltage
■
Accessories (Order Separately)
Name/specifications
Flush Mounting Adapter
Mounting Track
Models
Y92F-31
50 cm (l) × 7.3 mm (t)
PFP-50N
1 m (l) × 7.3 mm (t)
PFP-100N
1 m (l) × 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Track Mounting/
Front Connecting Socket
8-pin
PF085A
Back Connecting Socket
8-pin
US08
8-pin
P3G-08
8-pin, finger safe type
P3G-08 with Y92A-48G (see note 1)
For PF085A Socket
Y92H-6
Hold-down Clip (see note 2)
Note:
1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket.
2. Hold-down Clips are sold in sets of two.
1
H3JA
H3JA
Specifications
■
Time Ranges
Rated time
1s
Time range
0.1 to 1 s
Rated time
Time range
3 min
0.3 to 3 min
0.5 to 5 min
3s
0.3 to 3 s
5 min
5s
0.5 to 5 s
10 min
1 to 10 min
10 s
1 to 10 s
30 min
3 to 30 min
30 s
3 to 30 s
60 min
6 to 60 min
60 s
6 to 60 s
3 hrs
0.3 to 3 hrs
■
Ratings
Rated supply voltage
24, 100 to 120 or 200 to 240 VAC (50/60 Hz);
12, 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
H3JA-8A
100 to 120 VAC:
200 to 240 VAC:
24 VAC:
24 VDC:
12 VDC:
H3JA-8C
100 to 120 VAC:
200 to 240 VAC:
24 VAC:
24 VDC:
Control outputs
2
Approx. 2.6 VA (1.1 W) at 120 VAC
Approx. 5.0 VA (1.5 W) at 240 VAC
Approx. 1.0 VA (0.9 W) at 24 VAC
Approx. 0.8 W at 24 VDC
Approx. 0.5 W at 12 VDC
Approx. 2.4 VA (0.9 W) at 120 VAC
Approx. 4.1 VA (1.1 W) at 240 VAC
Approx. 1.2 VA (1.0 W) at 24 VAC
Approx. 0.8 W at 24 VDC
H3JA-8A: 7 A at 250 VAC, resistive load
H3JA-8C: 5 A at 250 VAC, resistive load
H3JA
■
H3JA
Characteristics
Accuracy of operating time
±2% max. (full scale)
Setting error
±7% max. (full scale) ±50 ms at 20°C
Influence of voltage
±2% max. (full scale)
Influence of temperature
±5% max. (full scale)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and between contact-carrying and control circuit, and between contacts of different poles)
750 VAC, 50/60 Hz for 1 min (between non-continuous contacts: H3JA-8A)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts: H3JA-8C)
Impulse withstand voltage
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
Noise immunity
±1.5 kV (between power terminals) and ±1.5 kV (between output terminals), square-wave noise
by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity
Destruction: 8 kV
Malfunction: 6 kV
Vibration resistance
Destruction: 10 to 55 Hz with 0.75-mm double amplitude in 3 directions for 1 hour each.
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude in 3 directions for 10 minutes each.
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Ambient temperature
Operating:
Storage:
–10°C to 55°C
–25°C to 65°C
Ambient humidity
Operating:
35% to 85%
Life expectancy
H3JA-8A
Mechanical:
Electrical:
H3JA-8C
Mechanical:
Electrical:
10,000,000 operations min.
60,000 operations min. (7 A resistive load at 250 VAC, 360 operations/h)
10,000,000 operations min.
100,000 operations min. (5 A resistive load at 250 VAC, 360 operations/h)
EMC
(EMI)
Emission Enclosure:
EN55011 Group 1 class B
Emission AC Mains:
EN55011 Group 1 class B
Harmonic Current:
EN61000-3-2
Voltage Fluctuation and Flickering:
EN61000-3-3
(EMS)
Immunity ESD:
EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst:
EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge:
EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Approved standard
UL508 (See note.), CSA C22.2 No. 14, conforms to EN61812-1 (Pollution degree 2)
Case color
Light gray (Munsell 5Y7/1)
Degree of protection
IP40 (panel surface)
Weight
H3JA-8A: Approx. 50 g
H3JA-8C: Approx. 60 g
Note:
The surrounding air temperature (operating) is −10 to 40°C.
3
H3JA
H3JA
Engineering Data
H3JA-8C
5,000
Switching operations (× 10 3 )
Switching operations (× 10 3 )
H3JA-8A
30 VDC
resistive load
1,000
120 VAC
resistive load
500
30 VDC
inductive
load
120 VAC
100 L/R = 7 ms inductive
load
cosφ = 0.4 250 VAC
50
resistive load
0
1
2
3
4
5
6
φ
7
Load current (A)
Load current (A)
Operation
■
Timing Chart
H3JA-8A
100 ms min.
Rt
Terminals
(2)-(7) (power)
Set time
Set time
(6)-(8) (NO)
(5)-(8) (NC)
Time UP indicator
(Orange)
Power ON indicator
(Green)
100 ms min.
H3JA-8C
Rt
Terminals
(2)-(7) (power)
Set time
(1)-(3) (NO)
(6)-(8)
(1)-(4)
(5)-(8) (NC)
Time UP indicator
(Orange)
Power ON indicator
(Green)
4
Set time
H3JA
H3JA
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
7
36
LED
36
■
60
14.2
4
0.7
30.5
32.8
Accessories (Order Separately)
Flush Mounting Adapter
Y92F-31
Adapter Y92F-31 shown with H3JA-8@ and
back connecting socket.
Panel Cutout
Recommended panel thickness: 1 to 5 mm
15.5
US08
46
40
13
44
US08
Connecting
Socket
37.4
22
11
91.3
Track Mounting/Front Connecting Socket
PF085A
Eight, M3.5 × 7
sems
Terminal Arrangement
(Top View)
Mounting Holes
Two, M4 or 4.5 dia. holes
Mounting Height of
Timer with Socket
Two, 4.5 dia.
holes
H3JA
Note: PF085A can be used
as a front connecting
socket.
Hold-down Clips (Set of Two Clips)
Y92H-6 for PF085A Socket
5
H3JA
H3JA
Back Connecting Socket
US08
US08
H3JA
+
Adapter
P3G-08
11
Terminal Arrangement
(Bottom View)
91.3
(When Y92A-48G mounted)
P3G-08
H3JA
+
Adapter
4.9
17
11
78.6
85.1
Finger Safe Terminal Cover
Conforming to VDE0106/P100
Twelve, 6.4 dia. holes
Y92A-48G
(Attachment for P3G-08
Socket)
48 × 48
47.7 × 47.7
34
16.5
24.6 27.6
47.4
Mounting Track
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
4.5
4.5
35±0.3
15
25
25
10
25
1,000 (500)
(see note)
25
10
15 (5)
(see note)
Note: The values shown in parentheses are for the
PFP-50N.
6
35±0.3
27±0.15
1
15
25
10
25 15
25
25
1,000
10
27
24
29.2
1
1.5
H3JA
H3JA
End Plate
PFP-M
Spacer
PFP-S
10
16
12
5
6.2
1.8
1
50
1.8
11.5
10 M4 × 8
pan head
screw
35.5 35.3
34.8
44.3
1.3
4.8
16.5
Installation
■
Terminal Arrangement
H3JA-8A
H3JA-8C
7
H3JA
H3JA
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L110-E1-01A In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Control Devices Division H.Q.
Analog Controller Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7080/Fax: (81)75-344-7189
0707